YC1 series (back rack type‐small/medium slag amount)
Machine outline diagram
Standard specifications (Contact for customized)
Spec. |
Model | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
YC1-30 | YC1-45 | YC1-60 | YC1-60L | YC1-90 | |||||||||||||||
Bar spacing(mm) | 4 | 6 | 8 | 4 | 6 | 8 | 4 | 6 | 8 | 4 | 6 | 10 | 4 | 6 | 10 | ||||
Capaclty(water) (m3 /hr) |
120 | 156 | 181 | 190 | 240 | 268 | 255 | 318 | 363 | 408 | 508 | 852 | 615 | 767 | 1267 | ||||
Effective screen width W1 (mm) |
300 | 450 | 600 | 600 | 900 | ||||||||||||||
Machine bottom width W2 (mm) |
495 | 645 | 795 | 795 | 1095 | ||||||||||||||
Channel width W3 (mm) | 540 | 690 | 840 | 840 | 1140 | ||||||||||||||
Effective water depth H1 (mm) | 500 | 500 | 500 | 800 | 800 | ||||||||||||||
Channel depth H2 (mm) | 570 | 570 | 870 | 870 | 870 | ||||||||||||||
Installation angle | 50° | ||||||||||||||||||
Bar screen drive (HP) | 1/4 | 1/4 | 1/4 | 1/2 | 1/2 | ||||||||||||||
Material | Standard | Stainless steel (SUS304) | |||||||||||||||||
Optional | Stainless steel (SUS316) 、Other special materials | ||||||||||||||||||
Reference dimension (mm) | Length L | 1350 | 1350 | 1350 | 1650 | 1650 | |||||||||||||
Width W | 810 | 960 | 1100 | 1100 | 1410 | ||||||||||||||
Height H | 1350 | 1350 | 1350 | 1700 | 1700 | ||||||||||||||
Reference weight( (kgs) | 150 | 190 | 220 | 280 | 350 |
Remarks: *Long-fiber, long-haired or rope-like substances in wastewater (sewage) are not suitable for this model, special care. *This model is designed for channel depths of approximately 1 meter *The above table shows the demand and construction work and water quality. *Please contact for the fence size and handling capacity for different applications *The following parameters must be provided when ordering: channel enthalpy, channel depth, installation angle, grid spacing, slagging height, maximum water level *Revised purchase type indication-Ex. YC1-30-6 (model - effective screen width - bar spacing). *The specification is accepted outside the specification, and the company reserves the right to design changes * Please request the actual installation dimension drawing before ordering |
Usages
Mainly used in hospitals, school facilities, social life water, small municipal water, small and medium-sized industrialwater, and pre-stage flow suspension and solid matter removal and protection post-treatment equipment (water pump) evacuation foreign object blockage. Generally used as a fine/medium grid. |